© Copyright Transpower Applications Ltd. All rights reserved.
WWW
Max Power W
300
500
700
© Copyright Transpower Applications Ltd. All rights reserved.
Special Features
- Universal AC mains input
- Designed for baseplate cooling
- 300-700W power versions with wide adjustment range
- -25°C standard, -40°C I grade
- 3 year warranty
Description
- The TPS380 is a power supply designed for use in applications where cooling through the baseplate is employed, such as in sealed boxes
- The power is derived from a power factor corrected, universal AC input to provide a well regulated DC output which is adjustable over a wide range
Electrical Specification Unit
- Universal AC input 100-230VAC, 50/60Hz with power factor correction
- EN55022 ENC emissions compliance, level B as standard
- Trim range 80-120%, (80-110% on 48V)
- Able to work through 2kV surges as standard, 4kV as an option
- DC on LED
Output
- 12VDC at 0 to 25A load adjustable 9.6V to 14.4V
- 12VDC at 0 to 42A load adjustable 9.6V to 14.4V
- 12VDC at 0 to 58A load adjustable 9.6V to 14.4V
- 28VDC at 0 to 11A load adjustable 22.4V to 33.6V
- 28VDC at 0 to 18A load adjustable 22.4V to 33.6V
- 28VDC at 0 to 25A load adjustable 22.4V to 33.6V
- 48VDC at 0 to 6.5A load adjustable 39V to 52.8V
- 48VDC at 0 to 10.5A load adjustable 39V to 52.8V
- 48VDC at 0 to 14.6A load adjustable 39V to 52.8V
Environmental Performance
- -25°C to +55°C ambient operation at full power
- Baseplate temperature useable at 80°C
- -40°C start and operation as low temperature option (I Grade)
Physical Specification
- 115 x 230mm baseplate
- Aluminium chassis
- Overall height 40mm
- 3 pin AC inlet on one end with DC output studs at other end for maximum safety clearance
- 0.1” pitch header for remote sense, trim connections and inhibit signals
- M6 output studs
- 6 off 4.5mm mounting holes
Part Number Code System
TPS380 - WWW - VV - CFGHIW (blank if none)
OPTIONS
C for PCB conformal coating
F for four (4) kV common mode surges
G for reserved function
H for hardened (extra component support for very rugged applications)
I for Industrial -40° to 80°C baseplate, 55°C ambient
W for wall mounted